The filter Everpure H54, with filter density of 0.5 microns, is able to reduce chlorine, cysts, limestone, suspended material and lead equal to 15ppm (0.010 mg/l)
Technical characteristics
– Technology: Precoat, activated carbon powder (PAC), Micro-Pure I
– Filter density: 0,5 microns
– Range: 2,835 litres (750 gallons)
– Range: 1,9 l./min. (0.5 gpm)
– Temperature: 35 – 100 ºC (2 – 38 ºC)
– Pressure: 10 – 125 psi (0.7 – 8.6 bar), non-shock.
– Cartridge dimensions hxd (mm.): 254×82,5
– Cartridge change: Every 6 months.
Attention
The filter should only be used with drinking water.
Filter installation
Headboard support
1. Loosen the centre screw (A),
2. unscrew and remove the two side screws (B),
3. position the fixing bracket (C),
4. screw and tighten the two screws (B),
5. tighten the screw (A) thoroughly,
NOTE – The support bracket (C) of the filter head is predisposed for fixing to the wall, through the slotted holes (D).
Verify that the area assumed for the placement of the filter is compatible with the rational “turn” of the pipes and their length.
Also check that the presence of the filter and its connections, does not hinder in any way other normal functions, during the exercise of activity.
When fixing the tested unit to the wall, the mounted filter must be at a distance from the ground of at least 10 cm, to allow its replacement. For fixing the bracket, use expansion plugs (in the case of fixing on masonry part), self-tapping screws (in the case of fixing on sheet), wooden screws (in the case of fixing on wooden walls).