The CSG membrane provides maximum performance with a high permeate flow and an excellent rejection rate.
Advanced CSG membrane technology and automated fabrication enable these elements to deliver high-level and consistent performance over time, on which equipment suppliers, Dealers of water treatment systems and components and end users can rely on it. CSG membranes are shipped dry (dry) for longer service life.
Technical data
- Series: CSG-2012-200
- Model: 2012-200 G
- Permeate flow: 200 GPD
- Applied pressure: 65 psi
- Rejection: 97 per cent
Test conditions
- Solution concentration: 250ppm naci
- Operating temperature: 25 ºC
- Permeate recovery: 35%
- pH: 7.5
- Range range: 15%
- Salt rejection rate tolerance: -2%
Maximum operating limits
- Membrane Type: Polyamide Thin-Film Composite
- Maximum operating temperature: 45 ºC – 113 ºF
- Maximum operating pressure: 125 psi – 8.6 bar
- Maximum power delivery: 2 gpm – 7.5 lpm
- Maximum feed silt density index (SDI): 5.0
- Free chlorine tolerance: <0.1ppm
Size
- Model: 2012-200 G
- A: 297 0.2 mm
- B 22.1 0.5 mm
- C 17 0.2
- D 47 0.6 mm
- E 255 1 mm